| 8.1.1 Component Removal, Through Hole Components, Vacuum Method |
|
Printed Board Type: R/F/W/C
Skill Level: Intermediate
Conformance Level: High
Revision: E
Revision Date: Oct 18, 2001
OUTLINE
 |
| Through Hole Component |
|
This procedure covers the general guidelines for
through hole component removal using a powered vacuum desoldering tool. There is
basically only one style of through hole component. Whether there are a few
leads or many, or whether the component is large or small, the component removal
principles are the same.
TOOLS &
MATERIALSCleaner Flux Microscope Solder Solder Removal
Tool, Vacuum Type with Tips Soldering Iron with Tips Wipes
PROCEDURE - Straight Leads, Standard Method
-
 |
| Figure 1: When the solder melts, activate the vacuum to remove the solder while oscillating the tip. |
|
Inspect the size of the solder joints on the component to be
removed. If the size of the solder joint fillets are minimal, it may be
desirable to add additional solder to form an "excess solder" joint. This will
improve the thermal linkage.
- Apply a small amount of liquid flux to the solder joints of the component to
be removed.
- Align the desolder tip with a component lead end and lightly make contact
with the solder joint. Keep the desolder tip off the pad by allowing it to slide
around on a film of solder.
CAUTION
Do not apply pressure with the solder extractor tip to the lands or other
conductive patterns.
- After the solder has melted, start a rotating or oscillating motion with the
desolder tip. Continue the rotating motion until a change in the "feel" of the
rotating motion occurs. At this instant the solder in the solder joint is
completely molten. Immediately activate the vacuum, extracting the solder from
the solder joint. (See Figure 1).
- Maintain rotation of the desolder tip while continuous vacuum is being
applied. This allows air to cool both the component lead and the plated-through
hole preventing the component lead from resweating to the side of the hole.
- After the solder has been extracted from the solder joint, remove the
desolder tip from the component lead while maintaining continuous vacuum.
- Maintain continuous vacuum for a few seconds to clear the desolder tip.
- Turn off the vacuum.
- Desolder each of the remaining component leads individually using a skipping
method to reduce thermal buildup at adjacent hole locations.
-
 |
| Figure 2: Lower the tip to melt the solder, then gently straighten the lead to a vertical position. |
|
Probe each component lead to be sure that they are not soldered
to the side of the plated hole and then remove component.
NOTE If each lead is not completely free, resolder
the joint and repeat steps 2 - 10.
- Clean the area.
PROCEDURE - Partial Clinch Leads, Standard
Method
- Inspect the size of the solder joints on the component to be removed. If the
size of the solder joint fillets are minimal, it may be desirable to add
additional solder to form an "excess solder" joint. This will improve the
thermal linkage.
-
 |
| Figure 3: Align the desolder tip with the fully clinched lead. Lower the tip to melt the solder and activate the vacuum to remove the solder from the joint. |
|
Apply a small amount of liquid flux to the solder joints of the
partially clinched leads.
- Align the desolder tip with the partially clinched lead. Lower the tip to
melt the solder. Then gently straighten the lead to a vertical position. (See
Figure 2). After each lead has been straightened, continue desoldering each lead
as described beginning in step 3 above.
PROCEDURE - Fully Clinch
Leads, Standard Method
- Apply a small amount of liquid flux to the solder joints of the fully
clinched leads.
-
 |
| Figure 4: Use a flat nose pliers to gently rotate the lead laterally break any remaining solder sweat joints. |
|
Align the desolder tip with the fully clinched lead. Lower the
tip to melt the solder and activate the vacuum to remove the solder from the
joint. (See Figure 3).
- Use a flat nose pliers to gently rotate the lead laterally break any
remaining solder sweat joints. (See Figure 4).
- Probe each component lead to be sure that they are not soldered to the side
of the plated hole and then remove component.
NOTE If each lead is not completely free, resolder
the joint and repeat steps 2 - 4. PROCEDURE - Straight Leads,
Auxiliary Heat Method Auxiliary heating may be required on solder
joints with a large thermal mass. This is most common on multilayer circuit
boards.
-
 |
| Figure 5: Place a soldering iron tip against the component lead and the desoldering tip over the lead end. |
|
Inspect the size of the solder joints on the component to be
removed. If the size of the solder joint fillets are minimal, it may be
desirable to add additional solder to form an "excess solder" joint. This will
improve the thermal linkage.
- Apply a small amount of liquid flux to the solder joints of the component to
be removed.
- Place a soldering iron tip against the lead of the component side of the
circuit board. (See Figure 5).
- Align the desolder tip with a component lead end and lightly make contact
with the solder joint. Keep the desolder tip off the pad by allowing it to slide
around on a film of solder.
CAUTION Do not apply pressure with
the solder extractor tip to the lands or other conductive patterns.
- After the solder has melted, start a rotating or oscillating motion with the
desolder tip. Continue the rotating motion until a change in the "feel" of the
rotating motion occurs. At this instant the solder in the solder joint is
completely molten. Immediately activate the vacuum, extracting the solder from
the solder joint.
- Maintain rotation of the desolder tip while continuous vacuum is being
applied. This allows air to cool both the component lead and the plated-through
hole preventing the component lead from resoldering to the side of the hole.
- After the solder has been extracted from the solder joint, remove the
desolder tip and the soldering iron tip from the component lead while
maintaining continuous vacuum on the desoldering tip.
- Maintain continuous vacuum for a few seconds to clear the desolder tip.
- Turn off the vacuum.
- Desolder each of the remaining component leads individually using a skipping
method to reduce thermal buildup at adjacent hole locations.
- Probe each component lead to be sure that they are not soldered to the side
of the plated hole and then remove component.
NOTE If each lead is not completely
free, resolder the joint and repeat steps 2 - 11.
- Clean the area.
EVALUATION
- In-process QA Inspection should be conducted to ensure component was removed
without evidence of damage to circuit board assembly or plated through hole.
|
|